13. , Annexin V-IF647/PI Cell Apoptosis Detection Kit, 50 T $500

SKU: G1514-50T
$500.00
In Stock
SKU: G1514-50T Category: Tags: ,

Description

Please click to see video about the product. I

video II

Product Information

Product Name Cat.No Spec.
Annexin V-IF647/PI Cell Apoptosis Detection Kit G1514-50T 50 T
G1514-100T 100 T

Introduction

Apoptosis is a normal physiological process that occurs during embryonic development and maintenance of tissue homeostasis. The process of apoptosis is accompanied by many morphological changes, among which the loss of cell membrane is one of the early characteristics of apoptosis. In normal cells, phosphatidylserine (PS) is only distributed on the inner side of the phospholipid bilayer of the cell membrane. However, in the early stage of apoptosis, PS will flip from the inner side of the lipid membrane to the outer side, exposing it to the outside of the cell. Annexin V is a Ca2+-dependent phospholipid-binding protein with high affinity for PS and it can specifically bind to cells exposed to PS. Therefore, Annexin V is used as one of the indicators to detect early apoptosis of cells. Propidium iodide (PI) is a nucleic acid dye that cannot penetrate normal cells with intact cell membranes and early apoptotic cells, but it can penetrate the cell membranes of late apoptotic and necrotic cells and stain cell nuclei.

This product uses a fusion protein composed of IF647 (enhanced Green Fluorescent Protein) and Annexin V as a detection probe to detect early apoptosis of cells. At the same time, PI was used to distinguish surviving cells from necrotic and late apoptotic cells. Due to the combined use of Annexin V-IF647 and PI, live cells showed negative staining (Annexin V-/PI-), early apoptotic cells showed single fluorescence positive (Annexin V+/PI-), and late apoptotic cells and necrotic cells showed double fluorescence Fluorescence positive (Annexin V+/PI+). This kit is suitable for flow cytometry or fluorescence microscopy. At the same time, since IF647 and Annexin V are 1:1 fusion, this product can also quantitatively detect apoptotic cells.


Storage and Handling Conditions

Transport with wet ice; store at 2-8℃ away from light, valid for 12 months.


Components

Component Number Component G1514-50T G1514-100T
G1514-1 Annexin V-IF647 250 μL 2×250 μL
G1514-2 Propidium Iodide(PI) 250 μL 2×250 μL
G1514-3 1×Binding Buffer 25 mL 2×25 mL
Instruction Manual 1 pc

Experimental Procedure

1. Suspension of cells: Take the cell suspension and collect the cells by centrifugation at 500 g for 5 min at 4℃;

Adherent cells: Collect cell culture supernatant first. After digestion with trypsin without EDTA (recommended G4002), it was combined with the cell culture supernatant, and the cells were collected by centrifugation at 500 g for 5 min at 4℃. Trypsin digestion time should not be too long to avoid false positives caused by excessive digestion.

2. Wash the cells twice with pre-cooled PBS (recommended G4202), and collect the cells by centrifugation at 500 g for 5 min at 4℃ each time;

3. Gently resuspend the cells with pre-cooled 1×Binding Buffer, and adjust the cell concentration to 1~5×106/mL;

4. Take 100 μL of cell suspension, add 5 μL Annexin V-IF647 and 5 μL PI, mix them gently, and protect from light at room temperature for 8-10 min;

5. Add 400 µL of pre-chilled 1×Binding Buffer, shake gently, and use flow cytometry or fluorescence microscope for detection within 1 hour.

Result Analysis

1. Flow Cytometry Detection

a. Select the appropriate voltage and adjust the light compensation during the flow cytometer detection and analysis. Except for the experimental group, it is recommended to set a negative control (without Annexin V-IF647 and PI labeling) to adjust the voltage; and the single standard control (with Annexin V-IF647 only cells as well as PI only cells) were used to regulate compensation;

b. Reference example of flow cytometry detection and analysis:

Jurkat T lymphoma cells were induced with 5 µM Camptothecin for 6 h. Referring to the above experimental steps, flow cytometry was used for detection. The results are shown in the following figure.

G1514-1.pngG1514-2.png

The maximum excitation wavelength of IF647 is 656 nm, and the maximum emission wavelength is 670 nm. The excitation maximum wavelength of the PI-DNA complex is 535 nm and the emission maximum wavelength is 615 nm. The two-chromatic scatter diagram was drawn by flow cytometry correlation analysis software, IF647 was located on the abscissa, and PI was located on the ordinate. In a typical experiment, live cells are non-fluorescent and the scatter is located in the lower left first quadrant. The apoptotic cells in the early stage have strong green fluorescence, and the scattered points are located in the second quadrant of the lower right. Late apoptotic cells and necrotic cells showed double fluorescence in red and green, and the scattered points were located in the upper right third quadrant.

2. Fluorescence Microscopy Detection

a. Add 5-10 µL of Annexin V-IF647 and PI double-stained cell suspension to the slide.

b. Cover with a coverslip.

c. Observe with a two-color filter under a fluorescence microscope. Annexin V-IF647 has a green fluorescence signal, and PI has a red fluorescence signal.


Note

1. The entire experimental process should be handled as gently as possible to avoid cell breakage, which may affect the experimental results.

2. Washing the cells with PBS cannot be omitted, and the residual PBS should also be removed as much as possible.

3. When using trypsin to digest cells, the experiment should be handled carefully and the digestion time should be controlled to avoid artificial damage to the cells. If the digestion time is too short, the cells need to be vigorously beaten to fall off, which may easily cause mechanical damage to the cell membrane; if the digestion time is too long, the cell membrane is also easily damaged. affect the test results. In addition, trypsin containing EDTA cannot be used. EDTA will affect the binding of Annexin V to PS.

4. After the adherent cells are stimulated by apoptosis, if some cells float, it is necessary to collect the cell culture supernatant and the adherent cells together for staining, which will make the results more accurate.

5. Annexin V-IF647 and PI are sensitive to light, please avoid light during operation. Testing should be performed as soon as possible after the reaction is complete.

6. Please wear a lab coat and disposable gloves during the experiment to avoid pollution and ensure safety.

 

For Research Use Only!

Product recommendation
Cat.No.
Product Name
Spec.
Operation
G1501-100T
Fluorescein (FITC) Tunel Cell Apoptosis Detection Kit
100 T
G1501-50T
Fluorescein (FITC) Tunel Cell Apoptosis Detection Kit
50 T
G1502-100T
TMR (Red) Tunel Cell Apoptosis Detection Kit
100 T
G1502-50T
TMR (Red) Tunel Cell Apoptosis Detection Kit
50 T
G1504-100T
CF488 Tunel Cell Apoptosis Detection Kit
100 T
G1504-50T
CF488 Tunel Cell Apoptosis Detection Kit
50 T
G1505-100T
CF640 Tunel Cell Apoptosis Detection Kit
100 T
G1505-50T
CF640 Tunel Cell Apoptosis Detection Kit
50 T
G1507-100T
DAB (SA-HRP) Tunel Cell Apoptosis Detection Kit
100 T
G1507-50T
DAB (SA-HRP) Tunel Cell Apoptosis Detection Kit
50 T
G1510-100T
Annexin V-EGFP/PI Cell Apoptosis Detection Kit
100 T
G1510-50T
Annexin V-EGFP/PI Cell Apoptosis Detection Kit
50 T
G1511-100T
Annexin V-FITC/PI Cell Apoptosis Detection Kit
100 T
G1511-50T
Annexin V-FITC/PI Cell Apoptosis Detection Kit
50 T
G1512-100T
Annexin V-PE/7-AAD Cell Apoptosis Detection Kit
100 T
G1512-50T
Annexin V-PE/7-AAD Cell Apoptosis Detection Kit
50 T
G1513-100T
Annexin V-IF488/PI Cell Apoptosis Detection Kit
100 T
G1513-50T
Annexin V-IF488/PI Cell Apoptosis Detection Kit
50 T
G1514-100T
Annexin V-IF647/PI Cell Apoptosis Detection Kit
100 T
G1514-50T
Annexin V-IF647/PI Cell Apoptosis Detection Kit
50 T
G1700-50T
Cell Cycle and Apoptosis Detection Kit
50 T

 

Shopping Cart
No products in the cart.